Is your freezer still somewhat cold but not reaching the right temperature? That’s a different problem โ see our guide on Kenmore Freezer Temperature Too Warm for a targeted diagnosis. This article is for freezers that have stopped freezing entirely, are barely cold, or have food thawing out.
Same symptom turns up on other brands too – start with our full write-up on GE refrigerator freezer compartment not freezing properly.
When a Kenmore freezer stops doing its one job, the clock starts ticking โ both on your food and on the underlying component. The good news: the top three causes of a Kenmore freezer not working account for nearly 80% of all cases. That means a systematic approach gets most people to the answer quickly, without replacing parts at random.
Work through this guide from the top. The first checks are free and take minutes. The more involved repairs come later.
Quick Troubleshooting Checklist โ Try These First
Before pulling panels or ordering parts, run through these five checks. In our experience at Appliance Repair Master, they resolve roughly 30% of “not freezing” calls without any further diagnosis:
- Is the freezer getting power? Open the door — does the interior light come on? If not, check the outlet with another device, then check the circuit breaker. A tripped breaker is a surprisingly common culprit, especially after a power fluctuation.
- Is the temperature set correctly? The target is 0°F (−18°C). Dial controls can get bumped accidentally. Set it to the coldest position and give the unit 24 hours to stabilize before drawing conclusions.
- Is the door sealing completely? A compromised door gasket lets warm air in continuously, overwhelming the cooling system. Do the dollar-bill test: close the door on a bill and try to pull it out. If it slides free without resistance, the seal is compromised.
- Are the condenser coils clean?Dirty condenser coils are one of the most overlooked causes of cooling failure. When coils are caked with dust, heat can’t dissipate — the compressor overheats and shuts down. Coils should be cleaned every 6–12 months.
- Is the freezer overpacked? Blocking the interior vents prevents cold air from circulating. Leave at least an inch of clearance around the vents at the back of the compartment.
If all five check out and the freezer still isn’t cooling, move to the full diagnosis below.
Why Your Kenmore Freezer Isn't Freezing โ All Possible Causes
1. Power Supply Issues
Start here, always. A freezer that appears dead โ no light, no hum, no response โ may simply have lost power.
Check in this order:
- Power cord fully seated in the outlet
- Outlet functional (test with a lamp or phone charger)
- Circuit breaker not tripped
- GFCI outlet not tripped (some kitchens and garages route freezer outlets through GFCI breakers)
- Power cord not damaged or pinched behind the unit
After a power outage: Surges can damage the start relay or the electronic control board even if the freezer appears to power back on. If the freezer runs but doesn’t cool after an outage, the relay is the first thing to test.
2. Defective Start Relay
The start relay is a small component plugged into the side of the compressor. Its job is to give the compressor the electrical kick it needs to start each cooling cycle. When it fails, the compressor clicks and gives up โ you’ll hear a brief hum followed by a click, repeating every few minutes.
The rattle test: Unplug the freezer, pull it away from the wall, remove the rear access panel, and locate the relay on the compressor body. Pull it straight off and shake it next to your ear. A rattle means it’s failed. No rattle doesn’t fully clear it โ also test with a multimeter for continuity.
This is one of the most cost-effective repairs in appliance service. On the KENMORE 253.23429100 (a Frigidaire-built upright), the start relay is among the first components to test when the compressor runs intermittently but the unit won’t hold temperature.
3. Cold Control Thermostat Not Working
The cold control thermostat monitors the interior temperature and signals the compressor and fan motors to run. If it’s stuck in the open position, the compressor never receives the call to start โ the freezer sits at room temperature with no cooling at all.
Test: Unplug the freezer. Disconnect the thermostat wiring and test for continuity with a multimeter at the coldest setting. A working thermostat shows continuity; an open circuit means it’s failed.
On Kenmore models with a dial control (most 253-series uprights), the thermostat is accessible behind the control housing inside the freezer compartment.ย
4. Faulty Thermistor (Temperature Sensor)
The thermistor is a small sensor that feeds real-time temperature data to the electronic control board. If it sends incorrect readings โ or no readings at all โ the board won’t call for cooling even when the freezer is warm.
Test: Resistance should change smoothly as temperature changes. A thermistor that reads the same resistance regardless of temperature, or shows an open circuit, needs replacement.ย
This is more common on electronically controlled models (795-series, Elite models) than on dial-controlled uprights.
5. Defrost System Failure
Frost-free Kenmore freezers run automatic defrost cycles to prevent ice from accumulating on the evaporator coils. When the defrost system fails โ whether it’s the heater, the bi-metal thermostat, or the defrost timer โ frost accumulates unchecked. Over days or weeks, it encases the evaporator coils completely, blocking all airflow. The compressor runs, but cold air can’t circulate.
Symptoms: Heavy frost on the back wall inside the freezer, the unit gradually getting warmer over a week or two, and the freezer running almost constantly.
How to confirm: Remove the rear interior panel. If the evaporator coils are buried in a solid block of ice, the defrost system has failed. A manual defrost (unplug, leave door open 24 hours) will temporarily restore cooling โ but if the frost returns within 2โ3 weeks, the underlying component needs replacement.
Test each component individually with a multimeter:
- Defrost heater: check for continuity
- Bi-metal thermostat: check for continuity at room temperature (should be closed)
- Defrost timer: advance manually with a screwdriver — if the compressor starts, the timer is stuck
Defrost system failure can also cause water leaks during defrost cycles โ see our water leak guide if you’re seeing both symptoms.
6. Evaporator Fan Motor Failure
The evaporator fan motor circulates cold air from the evaporator coils throughout the freezer compartment. If it fails, the coils get cold but the rest of the freezer doesn’t โ you’ll notice the area near the back panel is colder than the front.
Diagnostic: Close the freezer door and listen. You should hear the fan running. Open the door โ it stops (the door switch cuts it off). Close it again โ it should restart within a few seconds. No sound after closing = fan has failed or is frozen over.
To confirm: Remove the rear interior panel and try to spin the fan blade manually. If it spins freely but the motor doesn’t run, the motor has failed. If it won’t spin, it’s frozen in ice โ defrost first, then retest. If the freezer is also making unusual noises, see our noise diagnosis guide.
7. Condenser Fan Motor Failure
The condenser fan draws air across the condenser coils and over the compressor to dissipate heat. When it fails, the compressor overheats and shuts down via thermal overload โ the freezer runs in short bursts, then stops cooling entirely.
For the wider picture on this brand, see what we’ve seen with Kenmore freezer temperature too warm.
Location: Bottom rear of the unit, next to the compressor. Accessible by removing the rear lower access panel.
Test: With the freezer running, listen for the fan at the back. If the compressor is running but the condenser fan isn’t, the motor has failed. Confirm with a multimeter continuity test.ย
ะกondenser fan motor failure accounts for 14% of Kenmore freezer “not working” cases โ making it the third most common cause overall.
8. Failed Electronic Control Board
The main control board governs every function: compressor cycling, fan operation, defrost timing, temperature display. When it fails, the freezer may stop cooling entirely, behave erratically, or show error codes.
Visual inspection first: Remove the board and look for burn marks, swollen capacitors, or corrosion at the connectors. Visible damage is a clear indicator. If the board looks clean but the freezer still isn’t responding, the board may have failed internally โ harder to confirm without substitution testing.
A malfunctioning electronic control board is the cause in 23% of Kenmore freezer failures โ second only to the compressor.
On Kenmore Elite models in the 795-series, the control board and compressor often fail in tandem โ replacing only one without addressing the other is a documented pattern that leads to repeat failures.
9. Failed Compressor
The compressor is the heart of the sealed system. When it fails, nothing gets cold โ the freezer sits at room temperature regardless of settings. A failed compressor typically presents as: no hum from the back of the unit, the unit is completely room temperature, and the start relay tests fine.
ะกompressor failure is the #1 cause of Kenmore freezers not working โ 42% of cases.
The KENMORE 795.74023.411 (LG-built Kenmore Elite) is one of the most extensively documented cases of premature compressor failure in the Kenmore lineup. The LG linear compressor fails at a high rate โ often within 3โ5 years of purchase. The KENMORE 795.73133.410 shows the same pattern: compressor running but not pumping refrigerant, both sections warming to room temperature.
Compressor replacement requires EPA-regulated refrigerant handling. This is not a DIY repair.ย
10. Sealed System Leak (Refrigerant)
If the compressor runs, the fans run, the defrost system is intact, and the freezer still won’t get cold โ a refrigerant leak in the sealed system is the likely explanation. The compressor is pumping, but there’s nothing to pump.
Signs: Partial frost on only one section of the evaporator coils (where refrigerant enters), oily residue near the compressor or condenser coils, and a freezer that gets slightly cool but never reaches 0ยฐF.
On the KENMORE 253.28432809, this is exactly the documented failure pattern: partial coil frosting on the left side only, freezer stabilizing at 40ยฐF after hours of running โ a classic low-refrigerant presentation.
Sealed system repair requires EPA certification and specialized equipment.ย
How to Fix a Kenmore Freezer That Won't Freeze (Step-by-Step)
Work from cheapest and easiest to most expensive and complex.
Step 1 โ Verify Power and Temperature Settings
Check the outlet, the breaker, and the thermostat dial. Set the temperature to 0ยฐF (โ18ยฐC). If the freezer has been off or unplugged, give it a full 24 hours to stabilize before concluding it isn’t cooling โ a fully loaded freezer can take that long to reach target temperature from room temp.
Step 2 โ Clean the Condenser Coils
Locate the coils at the bottom rear of the unit (or behind the kick plate on some models). Unplug the freezer, remove the rear lower access panel, and vacuum the coil fins with a brush attachment. Work gently โ the fins bend easily. This alone can restore cooling if the compressor was shutting down from overheating.
Kenmore recommends cleaning condenser coils every 6โ12 months. In dusty environments or homes with pets, every 3โ6 months is more realistic.
Step 3 โ Test and Replace the Start Relay
Pull the relay from the compressor, shake it (rattle = bad), and test with a multimeter for continuity. If it fails either test, replace it.ย
Step 4 โ Test the Thermostat and Thermistor
For the cold control thermostat: disconnect the wiring and test for continuity at the coldest setting. For the temperature sensor (thermistor): test resistance at room temperature and compare to the spec in your model’s service manual. Resistance should change as temperature changes โ a flat reading indicates failure.
Step 5 โ Inspect the Defrost System
Remove the rear interior panel and inspect the evaporator coils. Heavy frost or a solid ice block confirms defrost system failure. Test the heater, bi-metal thermostat, and timer individually with a multimeter. Replace only the failed component โ don’t replace all three at once without testing.
Step 6 โ Check the Evaporator and Condenser Fan Motors
Listen for fan operation with the door closed. Test each motor with a multimeter โ no continuity means the motor has failed. The evaporator fan motor is behind the rear interior panel; the condenser fan is at the bottom rear of the unit.
Step 7 โ Inspect the Control Board
Remove the board and inspect visually for burn marks, swollen capacitors, or corroded connectors. If visible damage is present, replace. If the board looks intact but all other components test fine, the board may have failed internally.
Kenmore Freezer Not Freezing After a Power Outage
Power outages are a specific scenario worth addressing separately โ we see a spike in service calls after every major storm in the Atlanta area.
What to do immediately:
- Unplug the freezer for 5 minutes, then plug back in (hard reset)
- Reset the thermostat to 0°F
- Check the circuit breaker — reset if tripped
- Listen for the compressor starting within 5–10 minutes of plugging in
If the freezer still won’t cool after a reset: A power surge may have damaged the start relay or the control board. If the relay is fine and the board shows burn marks or the freezer behaves erratically, the board is the likely casualty.
Power surges can also damage the thermistor โ a less obvious failure that causes the board to receive incorrect temperature data and never call for cooling.
Kenmore Freezer Not Freezing โ Repair Costs at a Glance
Repair | DIY Cost | Professional Cost |
Condenser coil cleaning | $0โ$10 | $75โ$150 |
Start relay | $10โ$40 | $80โ$250 |
Thermostat | $15โ$70 | $100โ$300 |
Thermistor / temperature sensor | $10โ$60 | $80โ$250 |
Fan motors (each) | $15โ$60 | $100โ$300 |
Defrost heater | $20โ$70 | $120โ$350 |
Defrost timer | $20โ$60 | $100โ$300 |
Control board | $100โ$300 | $250โ$550 |
Compressor | Pro only | $300โ$800 |
Sealed system repair | Pro only | $400โ$800+ |
Kenmore Freezer Not Freezing by Model Type
Kenmore Upright Freezer (253-Series, Frigidaire-Built)
The 253-series frost-free uprights are the most common Kenmore freezer in service. The most frequent causes of cooling failure on these models:
- Defrost system failure — the heater or bi-metal thermostat fails, ice encases the evaporator coils, airflow stops
- Start relay failure — especially on units 8–12 years old
- Sealed system issues — partial coil frosting (one side only) is the telltale sign
On 253-series models, the evaporator coils and defrost components are behind the rear interior panel โ accessible with a Phillips screwdriver and about 20 minutes of work.
Kenmore Chest Freezer
Chest freezers have simpler mechanics than uprights — most models are not frost-free, which eliminates the entire defrost system as a variable. The primary suspects when a chest freezer stops cooling:
- Compressor failure — the most common cause; no hum from the unit, completely room temperature
- Start relay — same rattle test applies; often the fix on units that click but won’t start
- Cold control thermostat — if the compressor won’t run at all despite power being confirmed
Chest freezers are generally more reliable than uprights precisely because of their simpler design. When they do fail, the diagnosis is usually faster.
Kenmore Elite Freezer (795-Series, LG-Built)
This is the model type that generates the most service calls in our experience. The LG-built 795-series โ including French door and bottom-freezer configurations โ has a well-documented history of LG linear compressor failure, often occurring within 3โ7 years of purchase.
The failure pattern on models like the KENMORE 795.74023.411 and KENMORE 795.73133.410 is consistent: the compressor runs (warm and vibrating) but fails to pump refrigerant. Both the freezer and refrigerator sections warm to room temperature. Fans operate normally. No error codes in many cases.
On these models, the control board often needs to be updated at the same time as the compressor โ a detail that’s easy to miss and leads to repeat failures if only one component is replaced. This is a sealed system repair that requires EPA-regulated equipment and professional service.
Kenmore Side-by-Side Freezer (106-Series, Whirlpool-Built)
Side-by-side models share a single cooling system between the freezer and refrigerator sections. When the freezer stops cooling but the refrigerator section is still somewhat cold, the damper control (also called the air diffuser) is a likely culprit โ it regulates airflow between the two sections and can fail in the closed position, starving the freezer of cold air.
Other common causes on side-by-side models:
- Evaporator fan failure — cold air doesn’t reach the freezer section
- Defrost system failure — ice blocks the evaporator, reducing airflow to both sections
- Compressor or sealed system — both sections warm simultaneously
If the freezer isn’t cold but the refrigerator is still working, start with the damper control and evaporator fan before assuming a compressor issue.
When to Call a Professional
Most of the repairs above are DIY-friendly. These are the exceptions:
- Compressor failure — requires EPA-regulated refrigerant handling; not a DIY repair.
- Sealed system leak — same requirement; also requires leak detection equipment.
- 795-series LG-built models — compressor + control board combination failures are complex to diagnose correctly without specialized tools.
- Control board failure you can’t confirm — if the board looks intact but the freezer still doesn’t respond, substitution testing is the only reliable method.
- Post-power-outage failures with multiple symptoms — surge damage can affect several components simultaneously; systematic professional diagnosis is faster than replacing parts one at a time.
The 50% rule: If the estimated repair cost exceeds 50% of what a comparable new freezer costs, and the unit is over 10 years old, replacement is usually the smarter financial decision. A new Kenmore upright freezer runs $400โ$700; a compressor replacement at $300โ$600 on a 12-year-old unit rarely makes economic sense.
Conclusion
A Kenmore freezer that stops freezing is almost always traceable to one of a handful of causes โ and the most common ones are also the cheapest to fix. Start with the free checks: power, thermostat setting, door seal, condenser coils. Then move to the start relay before considering anything more involved.
For frost-free upright models, defrost system failure is the most likely culprit when the freezer gradually gets warmer over days. For Kenmore Elite 795-series models, the LG linear compressor is the documented weak point โ and it almost always requires professional service.
The step-by-step repair sequence in this guide is ordered by complexity for a reason: most people find their answer in the first three steps. If you’ve worked through all ten causes and the freezer still isn’t cooling, the sealed system is the remaining explanation โ and that’s where a technician with EPA certification and the right equipment makes the difference.
Related guides
FAQ
1. My Kenmore freezer is running โ I can hear it โ but nothing inside is freezing. What's most likely wrong?
A freezer that runs but doesn’t cool is one of the most common presentations we see. The compressor is operating, but something is preventing cold air from reaching the food. The most likely causes, in order: defrost system failure with ice blocking the evaporator coils, evaporator fan motor failure, or a failing compressor that’s running but not pumping refrigerant effectively. Start by removing the rear interior panel and checking whether the evaporator coils are encased in ice โ that alone answers the question in most cases.
2. My Kenmore upright freezer has heavy frost on the back wall inside, but the food isn't frozen. Is that a defrost problem?
Yes โ that’s the classic defrost system failure pattern. The frost you’re seeing is ice that should have been melted during automatic defrost cycles. It’s now blocking airflow across the evaporator coils, so the compressor runs but cold air can’t circulate. A manual defrost (unplug, door open for 24 hours) will confirm it โ if the freezer cools normally for a few weeks and then the frost returns, the defrost heater, bi-metal thermostat, or timer has failed and needs replacement.
3. My Kenmore Elite French door freezer stopped cooling. The compressor feels warm and is vibrating, but nothing is getting cold. Is this fixable?
This is the documented LG linear compressor failure pattern on 795-series Kenmore Elite models. The compressor is running but not pumping refrigerant โ it feels warm because it’s working, but it’s not producing any cooling effect. This requires professional sealed system repair: compressor replacement plus a control board update. Given the documented history of this failure on these models, get a repair estimate and compare it to replacement cost before committing.
4. How long should a Kenmore freezer last before needing major repairs?
A well-maintained Kenmore upright or chest freezer typically runs 15โ20 years. The 795-series LG-built Elite models are the exception โ compressor failures on these units have been documented as early as 3โ5 years. For any freezer over 10 years old, weigh the repair cost against replacement: if the repair exceeds 50% of a comparable new unit’s price, replacement is usually the better investment.
5. My Kenmore side-by-side freezer isn't freezing, but the refrigerator side is still somewhat cold. Does that narrow it down?
Significantly. When one section is cold and the other isn’t, the compressor and sealed system are usually not the problem โ they serve both sections. The most likely causes are a failed damper control (stuck closed, blocking airflow to the freezer), an evaporator fan that’s stopped circulating cold air, or a defrost system failure that’s blocked airflow on the freezer side specifically. Start with the damper control and evaporator fan before assuming anything more serious.